Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
RGO (Porto Alegre) ; 71: e20230025, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1449011

ABSTRACT

ABSTRACT Objectives: To evaluate the translucency, contrast ratio and masking ability of a translucent zirconia with different thicknesses. Methods: Disc shaped specimens (n= 3) with 10 mm (Ø) x 1.5 mm, 1 mm and 0.7 mm (thickness) were manufactured simulating all-ceramic simplified restorations. Substrate discs (n= 2; Ø: 10 mm; thickness: 2 mm) were simulated with composite resin shades: A2 (positive control) and C4; and metal alloys: silver (Ni-Cr) and golden (Cu-Al). Optical properties of the 9 translucent zirconia specimens placed on the 3 different substrates were analyzed by a spectrophotometer. The color variation (ΔE00) between each ceramic structure over the positive control substrate (A2) and over the dark backgrounds (C4, silvery, golden) were obtained as to their ceramic masking ability and subjected to non-parametric Kruskal Wallis test (5%). The translucency parameter (TP00) and contrast ratio (CR) of the different thicknesses of the ceramic discs were also collected and analyzed by one-way ANOVA and the Tukey test (5%). Results: The translucent zirconia showed greater opacity in the thickness of 1.5 mm, although it was not statistically different between 0.7 and 1.0 mm. All dark backgrounds significantly affected the final color of the simplified restoration in all evaluated thicknesses. However, the increase in ceramic thickness showed a decrease in ΔE00 values for all substrates. Conclusion: The translucent zirconia was not able to mask the dark substrates, independent of the evaluated thickness.


RESUMO Objetivos: Avaliar a translucidez, razão de contraste e capacidade de mascaramento de uma zircônia translúcida com diferentes espessuras. Métodos: Espécimes em forma de disco (n= 3) com 10 mm (Ø) x 1,5 mm, 1 mm e 0,7 mm (espessura) foram confeccionados simulando restaurações simplificadas em cerâmica pura. Discos de substrato (n= 2; Ø: 10 mm; espessura: 2 mm) foram simulados com as cores de resina composta: A2 (controle positivo) e C4; e ligas metálicas: prata (Ni-Cr) e ouro (Cu-Al). As propriedades ópticas dos 9 espécimes de zircônia translúcida posicionados nos 3 substratos diferentes foram analisadas por um espectrofotômetro. A variação de cor (ΔE00) entre cada espécime cerâmico sobre o substrato controle positivo (A2) e sobre os fundos escuros (C4, prateado, dourado) foi calculada quanto à capacidade de mascaramento da cerâmica e submetida ao teste não paramétrico de Kruskal Wallis (5%). O parâmetro de translucidez (TP00) e a razão de contraste (CR) das diferentes espessuras dos discos cerâmicos também foram coletados e analisados por ANOVA de uma via e teste de Tukey (5%). Resultados: A zircônia translúcida apresentou maior opacidade na espessura de 1,5 mm, embora não tenha sido estatisticamente diferente entre 0,7 e 1,0 mm. Todos os fundos escuros afetaram significativamente a cor final da restauração simplificada em todas as espessuras avaliadas. No entanto, o aumento da espessura da cerâmica mostrou uma diminuição nos valores de ΔE00 para todos os substratos. Conclusão: A zircônia translúcida não foi capaz de mascarar os substratos escuros, independente da espessura avaliada.

2.
RGO (Porto Alegre) ; 71: e20230022, 2023. graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1449017

ABSTRACT

ABSTRACT The CAD/CAM technology arose from the need to develop materials with better mechanical and optical properties that could be used for making monolithic restorations. Several materials have been used for milling indirect restorations in prefabricated blocks. Among them, lithium silicate reinforced with zirconia. Due to its recent introduction in the market, this case report aimed to present a detailed clinical protocol for the execution of a ceramic onlay of this material using CAD/CAM technology. A 57-year-old female patient sought care with extensive restoration in composite resin (BOMD) of tooth 15 maintained for almost two years. However, due to bruxism, constant dental tightening, the extension of the direct restoration and the need for improved esthetics, it was proposed to replace it with an indirect ceramic onlay restoration. Prophylaxis and choice of the color of the patient's dental substrate were performed. Afterwards, the dental preparation was made and polished. Subsequently, the molding was made with addition silicone and the provisional restoration confectioned. Once the stone model was obtained, it was scanned and the ceramic onlay restoration was milled using CAD/CAM technology. Finally, the restoration was stained and cemented over the preparation. After 2 years, the restoration remained stable, with no evidence of color mismatch, marginal discoloration, marginal cleft, caries or fracture, proving the effectiveness of the treatment in this time interval. The correct indication of the ceramic material combined with the use of CAD/CAM technology facilitated the restorative process, restoring function and the esthetics desired by the patient.


RESUMO A tecnologia CAD/CAM surgiu da necessidade de desenvolvimento de materiais com melhores propriedades mecânicas e ópticas que pudessem ser utilizados para confecção de restaurações monolíticas. Diversos materiais têm sido utilizados para fresagem de restaurações indiretas em blocos pré-fabricados. Dentre eles, o silicato de lítio reforçado com zircônia. Devido a sua recente introdução no mercado, este relato de caso objetivou apresentar um protocolo clínico detalhado para a execução de uma onlay cerâmica desse material utilizando a tecnologia CAD/CAM. Paciente, 57 anos, sexo feminino, procurou atendimento com extensa restauração em resina composta envolvendo as faces (MODV) do dente 15 mantida por quase dois anos. Contudo, em virtude do bruxismo, do apertamento dental constante, da extensão da restauração direta e da necessidade de melhora na estética, foi proposto a substituição por uma restauração indireta em cerâmica do tipo onlay. Foi realizada a profilaxia e escolha da cor do substrato dental da paciente. Em seguida o preparo dental foi confeccionado e polido. Posteriormente foi feita a moldagem com silicone de adição e a confecção do provisório. Com a obtenção do modelo, este foi escaneado e fresada a onlay cerâmica pela tecnologia CAD/CAM, que posteriormente foi maquiada e cimentada sobre o preparo. Após 2 anos, a restauração permaneceu estável, sem evidência de incompatibilidade de cor, descoloração marginal, fenda marginal, cárie ou fratura, comprovando a eficácia do tratamento neste intervalo de tempo. A correta indicação do material cerâmico aliada ao uso da tecnologia CAD-CAM facilitou o processo restaurador devolvendo função e a estética desejada pela paciente.

3.
RGO (Porto Alegre) ; 71: e20230020, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1449027

ABSTRACT

ABSTRACT Objective: This study assessed whether the use of a silane coupling agent influence the bond strength of two universal adhesives to ceramic or resin CAD/CAM blocks. Methods: Forty-eight samples were obtained from each resin nano-ceramic hybrid block (RCBs) and lithium disilicate ceramic blocks (LD). Samples were treated with silane with MDP (Monobond - S-MDP), silane without MDP (Prosil - PS), and no silane application (Control - Ctr) followed by universal adhesive with silane (UAS) and without silane (UA) (n=8). Three polyurethane tubes (1.5 mm of internal diameter) were positioned in each sample treated surface and filled with a dual cured resin cement. Bond strength was assessed by microshear bond strength test and failure analysis was performed for all samples. Results: For the RCBs, UAS presented the highest bond strength values (p=0.004). Silane application was not significant in bond strength values (p=0.444). For LD, silane application was significant in bond strength values (p<0.001), but the adhesive was not (p=0.066). Failure analysis showed high prevalence of adhesive failures for both substrates. Conclusion: A silane-containing universal adhesive promoted the best bond strength results to the resin nano-ceramic hybrid block. For bonding to a glass-ceramic CAD/CAM material, additional silane (without MDP) application presented the best results.


RESUMO Objetivo: Este estudo avaliou se o uso de um agente de união silano influencia na resistência de união de dois adesivos universais a blocos CAD/CAM cerâmicos ou resinosos. Métodos: Quarenta e oito amostras foram obtidas de blocos resinosos (RCBs) e cerâmicos de dissilicato de lítio (LD). As amostras foram tratadas com silano contendo: MDP (Monobond - S-MDP), silano sem MDP (Prosil - PS) ou sem aplicação de silano (Control - Ctr) seguido de adesivo universal com silano (UAS) ou sem silano (UA) (n=8). Três tubos de poliuretano (1,5 mm de diâmetro interno) foram posicionados em cada superfície tratada da amostra e preenchidos com um cimento resinoso dual. A resistência de união foi avaliada pelo teste de microcisalhamento e a análise de falha foi realizada para todas as amostras. Resultados: Para os RCBs, UAS apresentou os maiores valores de resistência de união (p=0,004). A aplicação de silano não foi significativa nos valores de resistência adesiva (p=0,444). Para LD, a aplicação de silano foi significativa nos valores de resistência de união (p<0,001), mas o adesivo não (p=0,066). A análise de falhas mostrou alta prevalência de falhas adesivas para ambos os substratos. Conclusão: O adesivo universal contendo silano promoveu os melhores valores de resistência adesiva ao bloco de resina. Para o bloco cerâmico, a aplicação adicional de silano (sem MDP) apresentou melhores resultados.

4.
RGO (Porto Alegre) ; 71: e20230050, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1514645

ABSTRACT

ABSTRACT Objectives: The objective was to evaluate the longevity of ceramic restorative materials in the manufacture of endocrown restorations, through an in vitro study on surface roughness and mechanical strength. Methods: Three restorative materials were evaluated and assigned to experimental groups (n=10 disc specimens): Leucite Reinforced Ceramic, Lithium Disilicate and Nanoceramic Resin. These restorative materials were evaluated for surface before and after aging (n=02 specimens) under a stereomicroscope. The specimens were submitted to the average surface roughness test (Ra) (n=10) in a contact roughness meter before and after aging. As well as the biaxial flexural strength test (n=10), after aging, up to a test speed of 0.5 mm/min. Aging was carried out in a thermocycler, with 5,000 cycles with baths of 5 °C ± 1 ° and 55 °C ± 1 °. Fragments after fracture were observed under a stereomicroscope. The data obtained were tabulated and analyzed using the Minitab statistical program. Results: The surfaces of the specimens do not show changes between the restorative materials and also in relation to aging. For the roughness data, the restorative material factors (p=0.867) and aging (p=0.321) were not statistically significant. The DIS group presented the highest values of fracture resistance (p=0.000), in relation to the LEU and REN groups, which were statistically similar. The same statistical pattern was identified for post-fracture fragment data (p=0.030). Conclusions: The aging factors and restorative material do not interfere with the surface roughness performance. However, the mechanical performance and number of fragments after fracture is affected by the restorative material.


RESUMO Objetivos: Objetivou-se avaliar a longevidade de materiais restauradores cerâmicos na confecção de restaurações endocrowns, através de um estudo in vitro sobre rugosidade superficial e resistência mecânica. Métodos: Três materiais restauradores foram avaliados e distribuídos em grupos experimentais (n=10 espécimes em disco): Cerâmica Reforçada por Leucita, Dissilicato de Lítio e Resina Nanocerâmica. Estes materiais restauradores foram avaliados quanto a superfície antes e após ao envelhecimento (N=2 espécimes) em estereomicroscópio. Os espécimes foram submetidos ao ensaio de rugosidade superficial média (Ra) (N=10) em rugosímetro de contato antes e após o envelhecimento. Como também, ao teste de resistência à flexão biaxial (N=10), após envelhecimento, em uma velocidade de ensaio de 0,5 mm/min. O envelhecimento foi realizado uma termocicladora, sendo 5.000 ciclos com banhos de 5 °C ± 1° e 55 °C ± 1°. Os fragmentos após fratura foram observados em estereomicroscópio. Os dados obtidos foram tabulados e analisados no programa estatístico Minitab. Resultados: As superfícies dos espécimes não mostram alterações entre os materiais restauradores e também em relação ao envelhecimento. Para os dados de rugosidade, os fatores materiais restauradores (p=0,867) e envelhecimento (p=0,321) não foram estatisticamente significativos. O grupo DIS apresentou os maiores valores de resistência à fratura (p=0,000), em relação aos grupos LEU e REN que foram estatisticamente semelhantes. O mesmo padrão estatístico foi identificado para os dados de fragmentos após a fratura (p=0,030). Conclusão: Os fatores envelhecimento e material restaurador não interferem quanto a performance da rugosidade superficial. No entanto, o desempenho mecânico e número de fragmentos após a fratura é afetado pelo material restaurador.

5.
Braz. dent. sci ; 26(2): 1-10, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1425780

ABSTRACT

Objective: To compare accuracy of selective laser sintered computer guided stents versus digital light processing stents in immediate implant placement in esthetic zone. Material and Methods: The patients were selected according to the eligibility criterias. The selected patients were randomly allocated to either digital light processing stents (test group) or selective laser sintered computer guided stents (control group). Proper examination and diagnostic records were done for each patient followed by triple scan protocol with cone beam computer tomography (CBCT). Planning and construction of tooth supported computer guided surgical stent was done by either digital light processing technique for test group or selective laser sintering for control group. Twenty implants were inserted following computer guided implant placement protocol. After post-operative CBCT pre and post images were merged using blue sky bio software. Linear and angular deviations between planned implant and actual implant positions were measured. Results: Tests were considered statistically significant if the p- value was less than 0.05. Difference in means were calculated for the analysis of continuous variables with corresponding 95% confidence intervals. There was no statistical difference between selective laser sintering and digital light processing groups in all measured terms. Conclusion : Within the limitations of this study, both techniques can be used for immediate implant placement with clinically satisfactory results decreasing the positional errors associated with immediate implant placement. (AU)


Objetivo: Comparar a acurácia de stents sinterizados por laser seletivo guiados por computador versus stents de processamento de luz digital na colocação imediata de implantes em região estética. Material e Métodos: Os pacientes foram selecionados de acordo com os critérios de elegibilidade. Os pacientes selecionados foram distribuídos aleatoriamente nos seguintes grupos: stents de processamento de luz digital (grupo experimental) ou stents sinterizados por laser seletivo guiados por computador (grupo controle). Os registros dos exames adequados e diagnósticos foram realizados para cada paciente seguido por um protocolo de varredura tripla com tomografia computadorizada de feixe cônico (TCFC).O planejamento e a construção do Stent cirúrgico guiado por computador com suporte dentário foram feitos pela técnica de processamento de luz digital para o grupo experimental ou sinterização a laser seletivo para o grupo controle. Vinte implantes foram inseridos seguindo o protocolo de colocação de implante guiado por computador. Após a TCFC pós-operatória, as imagens pré e pós foram mescladas usando o software blue sky bio. Foram medidos os desvios lineares e angulares entre o implante planejado e as posições reais do implante. Resultados: Os testes foram considerados estatisticamente significativos se o valor de p fosse menor que 0,05. A diferença nas médias foi calculada para a análise das variáveis contínuas com intervalos de confiança de 95%. Não houve diferença estatística entre os grupos de sinterização a laser seletivo e processamento digital de luz em todos as variáveis mensuradas. Conclusão: Dentro das limitações deste estudo, ambas as técnicas podem ser utilizadas para colocação imediata de implantes com resultados clinicamente satisfatórios diminuindo os erros posicionais associados colocação imediata de implantes. (AU)


Subject(s)
Computer-Aided Design , Surgery, Computer-Assisted , Cone-Beam Computed Tomography , Drug-Eluting Stents , Immediate Dental Implant Loading
6.
Braz. dent. sci ; 26(2): 1-9, 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1425975

ABSTRACT

Aim: The present split-mouth case report aims to describe the clinical and radiographic long-term outcomes of the implant rehabilitation of two mandibular premolars in which the digital workflow was used to apply different prosthetic protocols. Case description: A female 42-year-old patient with the absence of both mandibular second premolars was submitted to guided surgery for the placement of platform-switching Grand Morse connection implants. Digital workflow was used for implant and prosthetic planning, applying early loading protocol 21 days after surgery. The implant on the right side received the final abutment at the time of surgery (without loading), whereas the implant on the left side had a healing abutment placed, which was replaced by a temporary abutment and then by a final abutment. Two months after surgery, both implants had final ceramic restorations delivered. The patient was followed clinically and radiographically for 30 months, presenting excellent hard and soft tissue outcomes, with bone level changes lower than 2mm for both implants. Conclusion: The use of digital workflow and early loading, made the present implant-supported rehabilitation predictable, safe and time-efficient, resulting in total patient satisfaction. Peri-implant bone level was observed to be stable after early loading protocol for both platform-switching connection implants inserted, despite the prosthetic protocol applied.(AU)


Objetivo: O presente relato de caso de boca dividida tem como objetivo descrever os resultados clínicos e radiográficos a longo prazo da reabilitação com implante de dois pré-molares inferiores em que o fluxo de trabalho digital foi usado para aplicar os conceitos de "one abutment-one time" em uma das reabilitações e troca de componente no outro. Descrição do caso: Paciente do sexo feminino, 42 anos, com ausência de ambos os segundos pré-molares inferiores, foi submetida à cirurgia guiada para colocação de implantes de conexão Grand Morse plataforma-switching. Foi utilizado fluxo de trabalho digital para planejamento de implante e prótese, aplicando protocolo de carga antecipada 21 dias após a cirurgia. O implante do lado direito recebeu o componente protético definitivo no momento da cirurgia (sem carga), enquanto o implante do lado esquerdo recebeu um cicatrizador, que foi substituído por um pilar provisório e depois por um componente definitivo. Dois meses após a cirurgia, ambos os implantes tiveram restaurações cerâmicas finais entregues. A paciente foi acompanhada clínica e radiograficamente por 30 meses, apresentando excelentes resultados de tecidos duros emoles, com alterações do nível ósseo inferiores a 2mm para ambos os implantes. Conclusão: O fluxo de trabalho digital e carregamento precoce, tornou a presente reabilitação implantossuportada previsível, segura e eficiente em termos de tempo, resultando em total satisfação do paciente. O nível ósseo peri-implantar foi observado como estável após o protocolo de carregamento inicial para ambos os implantes de conexão plataforma-switching inseridos, independente do protocolo protético aplicado. (AU)


Subject(s)
Humans , Female , Adult , Prostheses and Implants , Dental Implants , Alveolar Bone Loss , Patient Satisfaction , Computer-Aided Design
7.
Revista Naval de Odontologia ; 49(1): 50-54, 2022/07/04.
Article in Portuguese, English | LILACS-Express | LILACS | ID: biblio-1379049

ABSTRACT

O objetivo do presente estudo foi avaliar a indicação do uso das cerâmicas feldspáticas em dentes posteriores, pela técnica CAD/CAM (Computer-aided design [CAD] e computer-aided manufacturing [CAM]) chairside, em uma unidade de alta demanda, por meio de uma revisão de literatura. Uma pesquisa avançada foi realizada a partir da base de dados do PubMed, compreendendo os últimos 15 anos e utilizando os seguintes termos MeSH para pesquisa: "dental crowns", "CAD/CAM system", "porcelain" e "review". Dos 47 artigos levantados inicialmente, 30 foram selecionados para compor a amostra final. A partir do presente estudo foi possível concluir que o uso das cerâmicas feldspáticas desenvolvidas pela técnica CAD/CAM é seguro em dentes posteriores, desde que respeitada a técnica. Esta técnica constitui-se em excelente opção para tratamento odontológico em instituições de alta demanda restauradora que possuem altos níveis de exigência e prontidão, promovendo celeridade, evitando o uso de restaurações provisórias, reduzindo também a quantidade de urgências em próteses.


The present study aims to evaluate the indication of the use of feldspathic ceramics in posterior teeth, by the CAD/CAM technique (Computer-aided design [CAD] and computer-aided manufacturing [CAM]), in a public institution, through a literature review. An advanced search was carried out in the PubMed database, covering the last 15 years and using the following MeSH search terms: "dental crowns", "CAD/CAM system", "porcelain" and "review". Thirty out of the 47 articles initially surveyed were selected to compose the final sample. From the present study, it was possible to conclude that the use of feldspathic ceramics developed by the CAD/CAM technique is safe in posterior teeth, whether the technique is respected. This technique is an excellent option for dental treatment in institutions of high restorative demand that have high levels of demand and readiness, promoting celerity, avoiding the use of temporary restorations, also reducing the number of urgencies in prosthesis.

8.
Acta ortop. bras ; 29(4): 211-218, Aug. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1339048

ABSTRACT

ABSTRACT Objective: This study aimed to explore the clinical application of preoperative precise design for 3D printing and thumb reconstruction, which could help manage the patients with thumb defect and achieve better function and appearance. Methods: This was a retrospective study of 20 patients who underwent the surgery of harvesting toe transplant and thumb reconstruction between January 2015 and December 2016. The 3D model of the thumb defect was created and printed. The dimensions of skin and bones from donor site were precisely designed as reference for surgical operation. The surgery was performed according to the model. Results: Perfect repair of defects was achieved with satisfying appearance and function. The reconstructed thumbs all survived (survival rate of 100%). Follow-up was 3-9 months. The maximum dorsiflexion was 8-30° and the maximum flexion was 38-58°. The two-point sensory discrimination was 9-11 mm. In total, 17 patients reposted "Excellent" satisfaction and three "Good", each for the reconstructed thumb and hand function, respectively. The satisfaction rate was 85%. Conclusion: Preoperative digital design and 3D printing according to the donor and recipient sites allowed a tailored operation. The operation was more precise, the appearance of the reconstructed thumb was good. Level of Evidence II, Retrospective Study.


RESUMO Objetivo: Este estudo explorou a aplicação clínica do desenho pré-operatório preciso para impressão 3D e reconstrução do polegar, para ajudar no controle e melhorar função e aparência. Métodos: Estudo retrospectivo de 20 pacientes submetidos à cirurgia de colheita de transplante de dedo do pé e reconstrução do polegar entre janeiro de 2015 e dezembro de 2016. O modelo 3D do defeito do polegar foi confeccionado e impresso. As dimensões da pele e dos ossos da área doadora foram precisamente projetadas como referência para a operação cirúrgica, realizada de acordo com o modelo. Resultados: O reparo perfeito foi alcançado com aparência e função satisfatórias. Todos os polegares reconstruídos sobreviveram (taxa de sobrevivência de 100%). O acompanhamento foi de 3-9 meses. A dorsiflexão máxima foi de 8-30° e a flexão máxima foi de 38-58°. A discriminação sensorial de dois pontos foi de 9-11 mm. No total, 17 pacientes reportaram índice "Excelente" e três índice "Bom" cada para a função reconstruída do polegar e da mão, respectivamente. O índice de satisfação foi de 85%. Conclusão: O design digital pré-operatório e a impressão 3D de acordo com os locais doador e receptor permitiram uma operação customizada. A operação foi mais precisa, com bom aspecto. Nível de Evidência II, Estudo Retrospectivo.

9.
Rev. Cient. CRO-RJ (Online) ; 6(1): 39-44, abr. 2021.
Article in English | LILACS, BBO | ID: biblio-1354415

ABSTRACT

Introduction: Biocorrosion is a multifactorial disorder that causes dissolution of hard tissues by extrinsic/ intrinsic factors. Traditionally, restoring biocorrosion wear involves invasive preparations. Objective: This case report aims to describe the rehabilitation of biocorrosion with a minimally invasive approach (thin occlusal and vestibular ceramic laminates) in a fully digital workflow using natural algorithms. Case report: A 23-year-old patient was presented to clinic with generalized tooth wear associated to dentin hypersensitivity. In anamnesis, eating disorders and acid food consumption were reported, supporting the diagnosis of biocorrosion. The restoration of worn tissues involved an additive approach (minimizing additional wear), using a face guided planning protocol and a natural tooth anatomy database to achieve greater naturalness at the final restorations. Rehabilitation of worn tissues was performed using occlusal, anterior ceramic veneers and additive composite restorations. The patient's natural teeth characteristics were preserved, restoring aesthetic and self-esteem, and after 2- year follow-up the patient remains very satisfied. Conclusion: Additive approaches involving the least amount of tissue wear are essential for the biocorrosion restoration. In addition, the integration of natural algorithms to digital workflows brings more aesthetic and precision to definitive restorations, overcoming one of the main challenges of milled aesthetic restorations: the naturalness.


Introdução: A biocorrosão é uma desordem multifatorial que causa a dissolução dos tecidos duros por fatores extrínsecos/intrínsecos. Tradicionalmente, a restauração do desgaste por biocorrosão envolve preparações invasivas. Objetivo: Este relato de caso tem como objetivo descrever a reabilitação da biocorrosão com uma abordagem minimamente invasiva (laminados cerâmicos oclusais e vestibulares finos) em um fluxo de trabalho totalmente digital usando algoritmos naturais. Relato de caso: Paciente de 23 anos foi atendido na clínica com desgaste dentário generalizado associado à hipersensibilidade dentinária. Na anamnese, foram relatados transtornos alimentares e consumo de alimentos ácidos, corroborando o diagnóstico de biocorrosão. A restauração de tecidos desgastados envolveu uma abordagem aditiva (minimizando o desgaste adicional), usando um protocolo de planejamento guiado pela face e um banco de dados de anatomia natural do dente para obter maior naturalidade nas restaurações finais. A reabilitação dos tecidos desgastados foi realizada usando facetas oclusais, anteriores de cerâmica e restaurações de resina composta aditiva. As características dos dentes naturais do paciente foram preservadas, restabelecendo a estética e a autoestima, e após 2 anos de acompanhamento o paciente continua muito satisfeito. Conclusão: As abordagens aditivas que envolvem o menor desgaste tecidual são essenciais para a restauração da biocorrosão. Além disso, a integração de algoritmos naturais aos fluxos de trabalho digitais traz mais estética e precisão às restaurações definitivas, superando um dos principais desafios das restaurações estéticas fresadas: a naturalidade.


Subject(s)
Tooth Erosion , Tooth Diseases , Computer-Aided Design , Dental Veneers , Tooth Wear
10.
ABCD (São Paulo, Impr.) ; 34(2): e1608, 2021. graf
Article in English, Portuguese | LILACS | ID: biblio-1345008

ABSTRACT

ABSTRACT Background: Heart dysfunction and liver disease often coexist because of systemic disorders. Any cause of right ventricular failure may precipitate hepatic congestion and fibrosis. Digital image technologies have been introduced to pathology diagnosis, allowing an objective quantitative assessment. The quantification of fibrous tissue in liver biopsy sections is extremely important in the classification, diagnosis and grading of chronic liver disease. Aim: To create a semi-automatic computerized protocol to quantify any amount of centrilobular fibrosis and sinusoidal dilatation in liver Masson's Trichrome-stained specimen. Method: Once fibrosis had been established, liver samples were collected, histologically processed, stained with Masson's trichrome, and whole-slide images were captured with an appropriated digital pathology slide scanner. After, a random selection of the regions of interest (ROI's) was conducted. The data were subjected to software-assisted image analysis (ImageJ®). Results: The analysis of 250 ROI's allowed to empirically obtain the best application settings to identify the centrilobular fibrosis (CF) and sinusoidal lumen (SL). After the establishment of the colour threshold application settings, an in-house Macro was recorded to set the measurements (fraction area and total area) and calculate the CF and SL ratios by an automatic batch processing. Conclusion: Was possible to create a more detailed method that identifies and quantifies the area occupied by fibrous tissue and sinusoidal lumen in Masson's trichrome-stained livers specimens.


Resumo Racional: Tecnologias de imagem digital têm sido introduzidas ao diagnóstico patológico, permitindo avaliações quantitativas objetivas. A quantificação de tecido fibroso em biópsias de fígado é extremamente importante para a classificação, diagnóstico e graduação de doenças crônicas hepáticas. Objetivo: Criar um protocolo computadorizado semi-automático para quantificação de fibrose centrolobular e dilatação sinusoidal em amostras de fígado coradas por Tricrômico de Masson. Método: Uma vez instaurada a fibrose, amostras de fígado foram coletadas, processadas histologicamente, coradas por Tricrômico de Masson e WSI (Whole Slide Images) foram capturadas por scanner digital patológico apropriado. Uma seleção aleatória das regiões de interesse (ROI) foi realizada. Os dados foram submetidos a uma análise de imagem assistida por software (ImageJ®). Resultados: A análise de 250 ROIs permitiu obter-se empiricamente as melhores configurações capazes de identificar fibrose centrolobular (FC) e lúmen sinusoidal (LS). Após o estabelecimento das configurações de padrão de cor, uma Macro de autoria própria foi gravada para definir as medidas (área da fração e área total) e calcular as razões de FC e LS por processamento em grupo/lote (batch mode). Conclusão: Foi possível criar um método detalhado capaz de identificar e quantificar a área ocupada por tecido fibroso e lúmen sinusoidal em espécimes de fígado coradas por Tricrômico de Masson.


Subject(s)
Humans , Image Processing, Computer-Assisted , Software , Fibrosis , Dilatation , Liver/pathology , Liver/diagnostic imaging , Liver Cirrhosis
11.
Braz. dent. sci ; 24(3): 1-7, 2021. ilus, graf
Article in English | BBO, LILACS | ID: biblio-1281352

ABSTRACT

Objective: The aim of this study was to evaluate whether the volume of odontoid process of the second cervical vertebra on CBCT images can be used for sex estimation. Material and Methods: The volume of odontoid process on CBCT images of 138 subjects was measured. In addition, the patients were classified into five age groups. The comparisons between the groups in relation to sex and age were performed by using Mann-Whitney's test and Kruskal-Wallis' test, respectively. The ROC curve was used to assess the sensitivity and specificity of the volume to determine the sex. Results: No statistically significant difference was observed between age and volume. Males had significantly larger volumes than females. Values of volume equal to or greater than 1.254 mm3 have sensitivity of 68.2% and specificity of 68.1% to determine male sex. Conclusion: The volume of the odontoid process tends to be larger in males than in females and can be used as sex estimation (AU)


Introdução: O objetivo deste estudo foi avaliar se o volume do processo odontóide da segunda vértebra cervical em imagens de TCFC pode ser usado para estimativa do sexo. Material e Métodos: O volume do processo odontóide em imagens CBCT de 138 indivíduos foi medido. Além disso, os pacientes foram classificados em cinco faixas etárias. As comparações entre os grupos em relação ao sexo e idade foram realizadas por meio dos testes de Mann-Whitney e Kruskal-Wallis, respectivamente. A curva ROC foi utilizada para avaliar a sensibilidade e especificidade do volume para determinar o sexo. Resultados: Não foi observada diferença estatisticamente significativa entre idade e volume. Os machos tiveram volumes significativamente maiores do que as fêmeas. Valores de volume igual ou superior a 1,254 mm3 apresentam sensibilidade de 68,2% e especificidade de 68,1% para determinação do sexo masculino. Conclusão: O volume do processo odontóide tende a ser maior no sexo masculino do que no feminino e pode ser usado como estimativa do sexo. (AU)


Subject(s)
Humans , Diagnostic Imaging , Sex Determination Processes , Imaging, Three-Dimensional , Cone-Beam Computed Tomography
12.
RGO (Porto Alegre) ; 69: e20210018, 2021.
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1287732

ABSTRACT

ABSTRACT Resin matrix ceramics consist in a polymeric matrix with predominantly inorganic refractory compounds which may include porcelain, glass, ceramics, and glass ceramics, and are divided into three subgroups: Nanoceramics, Vitroceramics, and Zirconia-silica. The aim of this study was to compare, through a literature review, the mechanical and biological properties of resin matrix ceramics, with glass matrix ceramics and polycrystalline ceramics. After reviewing 44 articles found in the US National Library of Medicine (PubMed) database (studies published in English, human clinical studies, in vitro or in vivo studies) that evaluated some properties of this material, such as elasticity modulus, wear resistance, adhesiveness, stain resistance and hardness, this article concluded that, although they belong to the same group, resin matrix ceramics are different from each other due to their microstructures. Moreover, when compared to other ceramic groups, it showed some superior properties, such as flexural strength, fatigue strength and internal adaptation.


RESUMO A cerâmica de matriz resinosa consiste em uma matriz polimérica contendo compostos refratários predominantemente inorgânicos que podem incluir porcelana, vidro, cerâmica e cerâmica vítrea. A cerâmica de matriz resinosa é subdividida em três subgrupos: nanocerâmica, vitrocerâmica e zircônia-sílica. O objetivo deste estudo foi comparar as propriedades mecânicas e biológicas, por meio de uma revisão da literatura, das cerâmicas de matriz resinosa comprando-as com cerâmicas de matriz vítrea e cerâmicas policristalinas. Após revisão de literatura de 44 artigos pesquisados na base de dados da Biblioteca Nacional de Medicina (PUBMED) dos EUA (estudos publicados no idioma inglês, estudos clínicos em humanos, estudos in vitro ou in vivo) que avaliaram algumas propriedades deste material, como módulo de elasticidade, resistência ao desgaste, adesividade, resistência a manchas e dureza, este estudo concluiu que, embora pertençam ao mesmo grupo, as cerâmicas de matriz resinosa têm características diferentes umas das outras devido às suas diferentes microestruturas. Além disso, quando comparada aos demais grupos cerâmicos, apresentou algumas propriedades superiores, como resistência à flexão, resistência à fadiga e adaptação interna.

13.
Araçatuba; s.n; 2021. 58 p. tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1435804

ABSTRACT

A aplicação de selantes de superfície poderá ajudar na diminuição da degradação superficial dos blocos de PMMA para CAD/CAM frente aos desafios de absorção de água, variação de temperatura e desafio erosivo causada pelo suco gástrico (frequente em pacientes com refluxo gastroesofágico (DRGE) ou bulimia. Contudo, poucos estudos na área odontológica foram realizados com essas variáveis, sendo necessário o aprofundamento sobre o assunto. Diante disso, o objetivo deste estudo foi avaliar o impacto de diferentes selantes de superfície (Biscovel LV e Palaseal) na preservação das propriedades mecânicas de polímero de PMMA para CAD/CAM, submetidos a termociclagem (T1 - 5.000 ciclos, de 5 e 55oC ; T2 ­ 10.000 ciclos, de 5 e 55oC) e desafio erosivo (DE1 - imersão em HCl 5% (pH=2,0) durante 45 horas e DE2- 91 horas), por meio da rugosidade de superfície (Ra), microdureza Knoop (MK), resistência flexural (RF) e módulo de elasticidade (ME). Foram confeccionados 90 espécimes quadrados (10x10x3 mm) para as análises de Ra e MK e 180 espécimes retangulares (25x2x2mm) para as análises de RF e ME. Os espécimes foram divididos em grupos (n=10) de acordo com o tratamento de superfície e envelhecimento. Os polimentos realizados foram: PA - pontas de borracha Astropol; PA+SB - polimento com PA + aplicação de selante de superfície Biscover LV e PA+SP - polimento com PA + aplicação de selante de superfície Palaseal. As análises foram realizadas após os tratamentos de superfície e após os períodos dos envelhecimentos. Os dados obtidos foram submetidos ao ANOVA (2 fatores), teste Bonferroni (α=0,05) e a análise de regressão linear simples. Na análise de Ra, em todos os períodos de termociclagem o grupo PA obteve os maiores valores de Ra e PA+SP os menores, com diferença significativa entre eles (p< 0.05). De acordo com a análise de regressão linear, todos os grupos apresentaram tendência linear crescente. Já após DE1 e DE2 os três grupos diferiram estatisticamente entre si (p< 0.05), sendo classificados em ordem crescente de rugosidade em PA+SP < PA+SB< PA. O grupo PA+SP manteve os valores de Ra no decorrer dos períodos de análises. Para RF, ocorreu diminuição significativa dos valores de RF do grupo PA após T1 e T2, diferindo estatisticamente dos demais grupos (p< 0.05). O desafio erosivo diminuiu de forma significante (p< 0.05) os valores de RF dos grupos PA e PA+SP após DE1 e, do grupo PA+SB após DE2. Não houve diferenças significativas nas análises de MK e ME, independente dos tratamentos de superfície e envelhecimentos. Conclui-se que os selantes de superfície foram capazes de preservar a rugosidade de superfície e resistência flexural de polímero de PMMA para CAD/CAM submetidos a termociclagem ou desafio erosivo(AU)


The application of surface sealants can help to reduce the surface degradation of PMMA blocks for CAD/CAM in the face of water absorption challenges, temperature variation and erosive challenge caused by gastric juice (common in patients with gastroesophageal reflux (DRGE) or bulimia. However, few studies in the field of dentistry have been conducted with these variables, requiring a more in-depth look at the subject. Therefore, the aim of this study was to evaluate the impact of different surface sealants (Biscovel LV and Palaseal) on the preservation of mechanical properties of PMMA polymer for CAD/CAM, subjected to thermocycling (T1 - 5,000 cycles, from 5 and 55oC; T2 - 10,000 cycles, from 5 to 55oC) and erosive challenge (DE1 - immersion in 5% HCl (pH=2.0) for 45 hours and DE2-91 hours), through surface roughness (Ra), Knoop microhardness (MK), flexural strength (RF) and modulus of elasticity (ME). The Ra and MK analyzes and 180 rectangular specimens (25x2x2mm) for the RF and ME analyses. Specimens were divided into groups (n=10) according to surface treatment and aging. The polishes performed were: PA - Astropol rubber tips; PA+SB - PA polish + application of Biscover LV surface sealant and PA+SP - polish with PA + application of Palaseal surface sealant. Analyzes were performed after surface treatments and after aging periods. The data obtained were submitted to ANOVA (2 factors), Bonferroni test (α=0.05) and simple linear regression analysis. In the analysis of Ra, in all thermocycling periods, the PA group had the highest values of Ra and PA+SP the lowest, with a significant difference between them (p< 0.05). According to the linear regression analysis, all groups showed an increasing linear trend. After DE1 and DE2, the three groups differed statistically from each other (p< 0.05), being classified in ascending order of roughness in PA+SP < PA+SB < PA. The PA+SP group maintained the Ra values throughout the analysis periods. For RF, there was a significant decrease in the RF values of the PA group after T1 and T2, differing statistically from the others groups (p< 0.05). The erosive challenge significantly decreased (p< 0.05) the RF values of the PA and PA+SP groups after DE1 and of the PA+SB group after DE2. There were no significant differences in the MK and ME analyses, regardless of surface treatments and aging. It was concluded that the surface sealants were able to preserve the surface roughness and flexural strength of PMMA polymer for CAD/CAM submitted to thermocycling or erosive challenge(AU)


Subject(s)
Polymers , Dental Prosthesis , Polymethyl Methacrylate , Computer-Aided Design , Dental Materials , Denture, Partial, Temporary , Flexural Strength
14.
RGO (Porto Alegre) ; 69: e20210052, 2021. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1346873

ABSTRACT

ABSTRACT The aim of this study was to describe a clinical protocol for fabrication of maxillary and mandibular dentures using CAD/CAM technology. Further, digital and conventional dentures fabricated for the same patient were compared. The comparison was based on patient's satisfaction, comfort, retention, number of follow-up sessions, masticatory performance and quality of life. No laboratorial step was needed for CAD/CAM fabrication and less sessions were required up to denture insertion. Compared to the conventional dentures, digital dentures provided better satisfaction, comfort and retention and required less follow-up sessions. Both dentures presented similar results about masticatory performance and quality of life. As a conclusion, digital denture is a viable treatment alternative for edentulous patients. However, controlled and randomized clinical trials are required to reveal the real benefits of this treatment alternative compared to the conventional denture.


RESUMO O objetivo deste estudo foi descrever um protocolo clínico para a fabricação de próteses superiores e inferiores usando a tecnologia CAD/CAM. Além disso, as próteses digitais e convencionais fabricadas para o mesmo paciente foram comparadas. A comparação foi baseada na satisfação, conforto, retenção, número de sessões de acompanhamento, desempenho mastigatório e qualidade de vida do paciente. Nenhuma etapa laboratorial foi necessária para a fabricação de CAD/CAM e menos sessões foram necessárias até a inserção da prótese. Comparadas às próteses convencionais, as próteses digitais proporcionavam melhor satisfação, conforto e retenção e exigiam menos sessões de acompanhamento. Ambas as próteses apresentaram resultados semelhantes sobre desempenho mastigatório e qualidade de vida. Como conclusão, a prótese digital é uma alternativa viável para o tratamento de pacientes desdentados. No entanto, ensaios clínicos controlados e randomizados são necessários para revelar os benefícios reais dessa alternativa de tratamento em comparação com a prótese convencional.

15.
RGO (Porto Alegre) ; 69: e20210032, 2021. graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1340563

ABSTRACT

ABSTRACT Digital dentistry is a ubiquitous phenomenon nowadays but it requires access to technologies and learning curve. To aid digital workflow implementation, digital steps can be progressively incorporated in conventional workflows. We aimed to demonstrate a multidisciplinary oral rehabilitation performed mixing conventional procedures with digital open-source software programs and low-cost devices. A 46-year-old female patient had photographs, intraoral scans, and cone-beam computed tomography obtained and used in combination with conventional clinical exams to develop a treatment plan. Power point software was used for digital smile planing and Horos for digital implant planning. The digital dataset were used to guide conventional clinical procedures (scaling and root planning, gingivoplasty, in-office tooth bleaching, fiber-post restoration, implant and bone graft placement, teeth preparation, and protheses design and milling). The inclusion of digital steps in the conventional workflow enabled the performance of rehabilitation procedures with reduced clinical time and increased predictability, favoring the overall workflow and the communication among the different dental specialties. A mixed workflow can progressively lead to an exclusively digital workflow as technologies become accessible and learning curve is coped.


RESUMO Atualmente, a Odontologia digital é um fenômeno onipresente, contudo exige acesso à tecnologia e curva de aprendizado. Para auxiliar na implementação de fluxos de trabalho digitais, etapas digitais podem ser progressivamente incorporadas nos fluxos de trabalho convencionais. Nosso objetivo foi demonstrar uma reabilitação oral multidisciplinar realizada combinando procedimentos convencionais e ferramentas digitais de baixo custo e acesso aberto. Uma paciente de 46 anos teve fotografias, exames intraorais e tomografia computadorizada de feixe cônico obtidos e usados em combinação com exame clínico convencional para desenvolvimento de um plano de tratamento. O software Power Point foi utilizado para o planejamento digital do sorriso e o Horos para o planejamento digital dos implantes. O conjunto de dados digitais foi usado para orientar a execução dos procedimentos clínicos convencionais (raspagem e alisamento radicular, gengivoplastia, clareamento dental, restauração com pino de fibra de vidro, inserção de implantes e enxerto ósseo, preparos protéticos e design e fresagem protética). A inclusão de etapas digitais no fluxo de trabalho convencional permitiu redução do tempo clínico na realização da reabilitação aliado à maior previsibilidade, favorecendo o fluxo de trabalho e a comunicação entre as diferentes especialidades odontológicas. O fluxo de trabalho misto pode progressivamente levar a um fluxo de trabalho exclusivamente digital à medida que as tecnologias se tornem acessíveis e a curva de aprendizado superada.

16.
Rev. nav. odontol ; 47(2): 26 a 34, out-nov 2020.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1378420

ABSTRACT

Os hábitos de vida modernos culminaram com o aumento na incidência da biocorrosão e na demanda por abordagens reabilitadoras estéticas minimamente invasivas. Do mesmo modo, o aprimoramento da Odontologia adesiva, materiais restauradores e sistemas Computer Aided Design and Computer Aided Manufacturing (CAD/CAM) permitiram resoluções estéticas com abordagens digitais eficazes e tempo clínico minimizado. Este trabalho tem como objetivo relatar uma reabilitação oral empregando laminados oclusais cerâmicos ultra finos posteriores para o restabelecimento da dimensão vertical, associados à abordagem sanduíche ântero-superior (laminados palatinos em compósito semi-diretos e laminados cerâmicos vestibulares) para a restauração da biocorrosão. A reabilitação foi realizada em CAD-CAM, utilizando a anatomia do banco de dados do software (biogenérico individual) para os elementos posteriores. Por outro lado, a anatomia anterior foi obtida pela cópia de dentes naturais através da integração entre o Digital Smile Design (DSD) e o sistema CAD-CAM (DSD-Natural Restoration). Portanto, o uso do sistema CAD-CAM no modo chairside conferiu agilidade ao procedimento reabilitador. Além disso, o DSD-Natural Restoration aprimorou a macro e microestética dos laminados cerâmicos.


Modern life increased the incidence of biocorrosion, demanding aesthetic and minimally invasive approach for the rehabilitation of these patients. At the same time, the improvementof adhesive dentistry, restorative materials and Computer Aided Design and Computer Aided Manufacturing (CAD/CAM) systems allowed the improvement on aesthetic with minimized time using effective digital approaches. This manuscript presents an approach with ultra-thin occlusal veneers to augmentation of vertical dimension and sandwich approach (semi-direct composite on palatal and ceramic on labial) to restore biocorrosion. The full mouth CAD-CAM rehabilitation involved posterior occlusal veneers using the software ́s anatomic database (biogeneric individual) and natural anterior algorithms obtained by integration between Digital Smile Design (DSD) and CAD-CAM (DSD - Natural Restoration). Therefore, the chairside mode is effective and less time consuming, associated to DSD-Natural Restoration improved anterior esthetic for labial ceramic veneers.

17.
RGO (Porto Alegre) ; 68: e20200038, 2020. tab
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1136019

ABSTRACT

ABSTRACT Computer aided design / computer aided manufacturing (CAD/CAM) systems are among the most technological advanced techniques in oral rehab today. Compared with conventional techniques, they can optimize the resistance and the adaptation of dental ceramics. Thus, their indications of use have been widened, making the technique more and more well-known and widespread. Therefore, the aim of this study is to present a literature review on comparative studies of the mechanical properties of ceramic systems produced by CAD / CAM. A search for scientific articles published between 2009 and 2019, in English, Spanish or Portuguese, was performed through the databases SCIELO, BIREME and PUBMED, using the descriptors "Ceramics", "Computer Aided Design" and " Partial Fixed Prosthesis ". Currently, all ceramic systems appear to have adequate strength for simple rehabilitations, but ceramic restorations produced by CAD/CAM systems present greater reliability than other manufacturing methods, presenting a wider array of indications due to their higher mechanical resistance. These systems, besides their versatility, also present an excellent aesthetic result, guaranteeing appropriate optical properties such as translucency and fluorescence, similar to natural teeth. Although the cost is a limiting factor, CAD/CAM technology is in full development and with high success rates that qualifies it as the state of art in oral rehabilitation.


RESUMO O sistema CAD-CAM (computer aided design/computer aided manufacturing), que significa desenho auxiliado por computação e manufatura auxiliada por computação, é um dos recursos mais tecnológicos e modernos na reabilitação oral atualmente. É uma alternativa que otimizou a resistência e a adaptação das cerâmicas odontológicas. Dessa maneira, suas indicações de uso têm-se ampliadas, tornando-o cada vez mais conhecido e difundido. O objetivo deste estudo é apresentar uma revisão da literatura sobre estudos comparativos das propriedades mecânicas dos sistemas cerâmicos produzidos por CAD/CAM. Foi realizada a busca de artigos científicos publicados entre 2009 e 2019, em inglês, espanhol ou português, nas bases de dados SCIELO, BIREME e PUBMED, utilizando os descritores: "Ceramics", "Computer Aided Design" e "Prótese Parcial Fixa". Atualmente todos os sistemas cerâmicos parecem ter uma adequada resistência para reabilitações simples, mas as restaurações cerâmicas produzidas por sistemas CAD/CAM apresentam maior confiabilidade do que outros métodos de fabricação; apresentando maiores possibilidades de indicações devido aos seus maiores valores de resistência mecânica. Esta tecnologia embora apresente o custo como um fator limitante, está em pleno desenvolvimento e já apresenta propriedades mecânicas suficientes e com índices de sucesso que a qualificam como o estado da arte em reabilitação oral.

18.
Araçatuba; s.n; 2020. 73 p. tab, graf, ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1434427

ABSTRACT

O objetivo desse estudo in vitro foi avaliar por meio da metodologia de ciclagem mecânica a adaptação marginal (vertical/horizontal) e resistência à fratura, verificando a decorrência e possíveis complicações protéticas de próteses parafusadas implantossuportadas (hexágono externo) confeccionadas por diferentes técnicas e materiais cerâmicos. Foram confeccionados 50 corpos de prova, pela técnica convencional e Computer aided design and Computer aided manufacturing (CAD-CAM) divididos em cinco grupos (n=10 por grupo) sendo MC (Metalocerâmica); ZrL (Coping fresado em zircônia com link mais aplicação de cerâmica feldspática); Zr (Coping fresado em zircônia mais aplicação de cerâmica feldspática); MZrL (Monolítica de zircônia com link); MZr (Monolítica de zircônia), os quais foram submetidos à ciclagem mecânica em uma angulação de 30°, a 37°C e submetidos a 5 x 106 ciclos com aplicação de carga de 150N a uma frequência de 2,0Hz. No capítulo 1 foram avaliados à adaptação marginal vertical e horizontal (µm) antes e após ciclagem mecânica em Microscópio Óptico Tridimensional (3D) e no capítulo 2 os padrões de falhas das cerâmicas em Estereomicroscópio e Microscópio eletrônico de varredura (MEV) pós ciclagem mecânica. Os dados quantitativos foram analisados quanto a distribuição de normalidade e adotou-se o teste mais adequado considerando o nível de significância de 0,05. Os resultados obtidos para o capítulo 1 foram que em relação a desadaptação marginal vertical antes da ciclagem mecânica (tempo inicial-T0), houve diferença significativa com maiores valores de desadaptação para MC (93,93±22,84µm) e MZrL (66,12±11,87µm), p<0.05, quando comparados à Zr (49,92±3µm) e MZr (49,76±3,9µm), unindo os grupos com (ZrL+MZrL: 63,04±9,33µm) e sem link (Zr+MZr: 49,84±3,38µm) comparados ao grupo controle (MC) houve diferença significativa entre todos os grupos, p< 0.05, com menores valores de desadaptação para o grupo sem link. Em termos de desadaptação marginal horizontal antes da ciclagem mecânica (tempo inicial - To), houve diferença significativa com maiores valores de desadaptação para o grupo MC (-130,275±34,97µm), p<0.05, e menores valores de desadaptação para o grupo MZr (- 10,35±23,14µm), p<0.05, quando comparados aos demais grupos, além disso para o grupo sem link (Zr: -70,27±22,61µ vs MZr: -10,35±23,14µ), houve diferença significativa (p<0.05) com menores valores de desadaptação para MZr. Unindo os grupos com (-75,98±14,17µm) e sem link (-40,31±37,73µm), foi identificada diferença significativa entre todos os grupos quando comparados ao controle (MC: -130,27±34,97µm), (p< 0.001), com menores valores para o grupo sem link. Em relação à comparação antes e após ciclagem (Tf-T0), para análise da adaptação marginal vertical, o grupo MC (10,05±5,74µm) foi o que apresentou maiores valores de desadaptação, p<0.05, quando comparado aos demais grupos, já para análise da adaptação marginal horizontal, o grupo Zr (3±13,97µm) apresentou diferença estatística, p<0.05, na comparação com ZrL (-4,48±13,59µm) e MZrL (-2,825±11,81µm), unindo os grupos com (- 3,65±12,72µm) e sem link (0,35±10,99µm), houve menores valores de desadaptação para o grupo sem link, p<0.05. Para o capítulo 2, um total de 14 amostras falharam (lascamento/fratura de cerâmica). Os grupos MZrL e MZr apresentaram significativamente menor associação de falhas, com apenas uma falha (MZr) (p=0.035), assim como em relação ao tipo de substrato, os grupos MZrL e MZr apresentaram menos falhas (p=0,011). O uso de links e o número de ciclos não indicaram diferenças significativas entre os grupos (p≥0,05). Para área da falha, houve diferença significativa para o grupo Zr (15,55m²), p=0,029, apresentando maior extensão de área quando comparado aos demais. Em relação ao local da falha o grupo MC apresentou uma maior quantidade de falhas, com 5 falhas na região de orifício do parafuso quando comparado aos demais (p=0,043), os quais apresentaram falhas em diferentes locais. Portanto, o uso da tecnologia CAD/CAM foi o que resultou em menores valores de desadaptação marginal vertical e horizontal, assim como para resistência à fratura com destaque para as coroas monolíticas de zircônia(AU)


The aim of this in vitro study was to evaluate, through the mechanical cycling methodology, the marginal fit (vertical / horizontal) and fracture resistance, verifying the outcome and possible prosthetic complications of screwed-retained prostheses (external hexagon) made by different techniques and ceramic materials. Fifty specimens were made using the conventional technique and Computer aided design and Computer aided manufacturing (CAD-CAM) divided into five groups (n = 10 per group) being MC (Metal-ceramics crowns); ZrL (Coping milled in zirconia with link and covered feldspar ceramic); Zr (Coping milled in zirconia with covered feldspar ceramic); MZrL (Monolithic zirconia with link); MZr (Monolithic zirconia), which were subjected to mechanical cycling at an angle of 30 °, at 37 ° C and subjected to 5 x 106 cycles with a 150N load application at a frequency of 2.0Hz. In chapter 1, the vertical and horizontal marginal fit (µm) were evaluated before and after mechanical cycling under a threedimensional optical microscope (3D) and in chapter 2 the failure modes by the stereomicroscope and scanning electron microscope (SEM) after mechanical cycling. Quantitative data were analyzed for normality distribution and the most appropriate statistical test was adopted considering the significance level of 0.05. The results obtained for chapter 1 were that in relation to vertical marginal misfit before mechanical cycling (initial time-T0), there was a significant difference with higher misfit values for MC (93.93 ± 22.84µm) and MZrL (66, 12 ± 11.87µm), p <0.05, when compared to Zr (49.92 ± 3µm) and MZr (49.76 ± 3.9µm), joining the groups with (ZrL + MZrL: 63.04 ± 9.33µm) and without link (Zr + MZr: 49.84 ± 3.38µm) compared to the control group (MC) there was a significant difference between all groups, p<0.05, with lower misfit values for the group without link. In terms of horizontal marginal misfit before to mechanical cycling (initial time - To), there was a significant difference with higher misfit values for the MC group (-130.275 ± 34.97µm), p<0.05, and lower misfit values for the group MZr (-10.35 ± 23.14µm), p < 0.05, when compared to the other groups, in addition for the group without a link (Zr: -70.27 ± 22.61µm vs MZr: -10.35 ± 23, 14µm), there was a significant difference (p< 0.05) with lower misfit values for MZr. Joining the groups with (-75.98 ± 14.17µm) and without link (-40.31 ± 37.73µm), a significant difference was identified between all groups when compared to the control (MC: -130.27 ± 34, 97µm), (p<0.001), with lower values for the group without a link. Regarding the comparison before and after cycling (Tf-T0), for analysis of vertical marginal fit, the MC group (10.05 ± 5.74µm) was the one with the highest misfit values, p <0.05, when compared to the others groups, already for analysis of the horizontal marginal adaptation, the Zr group (3 ± 13.97µm) showed statistical difference, p <0.05. For chapter 2, a total of 14 samples failed, the groups MZrL and MZr showed significantly less association of failures, with only one failure (MZr), p = 0.035, as well as in relation to the type of substrate, the groups MZrL and MZr showed fewer failures (p = 0.011). The use of links and the number of cycles did not indicate significant differences between the groups (p≥0.05). For the chipping and/or fracture dimensions, there was a significant difference for the Zr group (p = 0.029) presenting a larger area of chipping when compared to the others. Regarding the location of the failure, the MC group showed a greater number of chipping in the screw orifice region when compared to the others (p = 0.043), which failed in different locations. Therefore, the use of the CAD / CAM system resulted in lower values of vertical and horizontal marginal maladjustment, as well as fracture resistance, with emphasis on monolithic crowns(AU)


Subject(s)
Ceramics , Dental Marginal Adaptation , Dental Prosthesis, Implant-Supported , Dental Prosthesis , Computer-Aided Design , Dental Restoration Failure , Crowns , Volume Electron Microscopy
19.
Biosci. j. (Online) ; 35(4): 1256-1261, july/aug. 2019. ilus
Article in English | LILACS | ID: biblio-1048930

ABSTRACT

Some areas of knowledge are usually related to a high degree of abstraction involved in the object studied. In the case of the embryology study, for instance, the students' learning difficulties are recurrent due to a lack of didactic resources, which may aid the interpretation process of the figures presented in related literature. Based on the motivation to improve university education, specially in the area of biological sciences, the present work aims to represent in three dimensions, stages of the human embryological development. SolidWorks 3D modeling software was used, as well as didactic material related to the subject of embryology, conception and human development, such as books, atlases and scientific papers. There weredesigned, in 3D software, models representing the stages of human embryonic development. This means ofproduction allowed the elaboration of exclusive anatomic models, with low cost (less than R$100,00 for more than 10 parts) and ease of visual interpretation. The models were designed in scale, such that it was possible to compare models that represent distinct periods of ontogenic development. It was possible to contribute to an improvement in the understanding of the topic of embryology for students with major related to health, through the visualization, in three dimensions, of models that are sometimes very expensive as physical pieces, or even nonexistent in market.


Algumas áreas do conhecimento, geralmente, estão relacionadas a um alto grau de abstração envolvido no objeto estudado. Para o caso do estudo de embriologia, por exemplo, é recorrente a dificuldade de aprendizagem dos estudantes, por falta de recursos didáticos, que possam auxiliar no processo de interpretação das figuras apresentadas em literatura relacionada. Partindo da motivação de melhorar o ensino universitário, sobretudo na área de ciências biológicas, o presente trabalho objetiva representar, em 3 dimensões, etapas do desenvolvimento embriológico humano. Foi utilizado o software de modelagem 3D, SolidWorks, além de material didático relacionado ao assunto de embriologia, concepção e formação do ser humano, como livros, atlas e artigos científicos. Foram projetados, em software 3D, modelos que representem etapas do desenvolvimento embrionário humano. Esse meio de produção permitiu a elaboração de modelos anatômicos exclusivos, com baixo custo e facilidade de interpretação visual. Os modelos foram projetados em escala, de tal modo que foi possível a comparação entre modelos que representem períodos distintos do desenvolvimento ontogênico. Foi possível contribuir com melhora do entendimento do tema de embriologia, para estudantes da área da saúde, por meio da visualização, em três dimensões, de modelos que por vezes são muito caros como peças físicas, ou mesmo, inexistentes no mercado.


Subject(s)
Teaching , Teaching Materials , Embryology , Computer-Aided Design , Printing, Three-Dimensional
20.
J. health inform ; 8(2): 66-72, abr.-jun. 2016. ilus, tab, graf
Article in Portuguese | LILACS | ID: biblio-1112

ABSTRACT

Objetivo: Este artigo apresenta o sistema de monitoramento de soro hospitalar OpenSerum. Trata-se de uma solução open source que faz uso de tecnologias de comunicação móvel para o acompanhamento em tempo real do serviço de infusão intravenosa de soro hospitalar. Método: Na primeira etapa, montou-se um circuito elétrico baseado em sensores infravermelhos para a monitoração da queda das gotas. Na segunda etapa, codificou-se um sistema servidor capaz de manter dados de configuração e enviar mensagens de texto informativas de status para dispositivos móveis cadastrados.  Resultados: O sistema de monitoramento permitiu detectar, por meio de mudanças na faixa de valores analógicos do receptor infravermelho, se o soro estava em atividade ou não. Conclusão: O sistema desenvolvido cumpriu com seus objetivos de monitoração, destacando a capacidade de interação com dispositivos móveis quando necessário para informar o status de atividade do soro monitorado.


Objectives: This paper presents the OpenSerum system for serum monitoring. It is an open source solution that uses mobile communication technologies for real-time monitoring of intravenous serum infusion service. Method: First, an electrical circuit was assembled based on infrared sensors in order to detect the fall of drops. Next, a server system was programed in order to maintain circuit configuration data and send textual messages with status information for mobile devices. Results: The monitoring system allows the detection, through changes in the range of analog infrared receiver values, whether the serum was active or not. Conclusion: The developed system reached its monitoring goals, highlighting the ability to interact with mobile devices when necessary to inform the serum activity status.


Objetivo: Ese artículo presenta el sistema de monitoreo de suero OpenSerum, una solución open source que hace uso de tecnologías de comunicación móviles para la monitorización en tiempo real de la infusión intravenosa de suero. Método: En la primera etapa, se creó un circuito eléctrico basado en sensores de infrarrojos para el seguimiento de la caída de las gotas. En la segunda, un sistema de servidor fue programado con el fin de mantener los datos de configuración de circuitos y enviar mensajes de texto con información de estado para dispositivos móviles. Resultados: El sistema de monitoreo permitió detectar por medio de cambios en la escala de valores analógicos del receptor infrarrojo, si el suero era o no en actividad. Conclusión: El sistema desarrollado cumplió con sus objetivos de monitoreo, poniendo de relieve la capacidad de interacción con dispositivos móviles cuando necesario para informar el status de actividad del suero.


Subject(s)
Infusion Pumps , Medical Informatics , Signal Processing, Computer-Assisted , Drug Monitoring , Biomedical Technology
SELECTION OF CITATIONS
SEARCH DETAIL